This page applies to the optional air purifier used with TOOCAA NOVA. It explains how to clean the purifier chamber and replace the top Purifier Filter.
Stop the job, switch off the machine and air purifier, disconnect power and wait for the purifier fan to stop completely.
Prepare a new Purifier Filter compatible with your purifier model, and a clean, soft, dry cloth.
Note: Disconnect power before opening, cleaning or replacing parts. This procedure cleans the purifier chamber and replaces the used top filter with a new one. Do not spray or pour cleaning liquid into the chamber, fan or electrical components.
Use a clean, soft, dry cloth to wipe dust and debris from the chamber walls, corners and accessible surfaces. Keep debris out of the fan opening at the bottom.
Figure 3 shows the chamber with the filter assembly removed. If a lower filter assembly must be temporarily removed to reach the cleaning area, note its original order and orientation, support it while lifting it out and reinstall it in the same position after wiping. Do not dismantle the other filter elements.
Figure 3: Purifier chamber cleaning area. Reinstall any temporarily removed lower filter assembly in its original position.
Check that the chamber is clean and dry, and that any lower filter assembly is back in its original position.
Lay the new top filter flat in its original location, covering the intended area. Check that the edges fit properly, with no curled edges, folds or visible gaps.
Figure 4: Fit the new top Purifier Filter flat in its original position.
Align and refit the lid. Check that the filter is not pinched, then fasten the latches on both sides.
Check that the lid and exhaust hose connections are secure. Remove tools and the used filter. Reconnect power and check that the purifier runs normally with normal exhaust airflow.
Figure 5: Refit the lid, fasten both latches and check that it is secure.
If the lid will not latch, disconnect power and check the positions of the filter assembly, filter and lid. Do not force it shut. If weak airflow, unusual noise or unusual odor remains after replacement, stop processing and check the exhaust hose connections. Contact TOOCAA support if the issue persists.
The new filter is flat and properly seated, without folds, curled edges or visible gaps. Lower filter assemblies retain their original order and orientation.
No cleaning tools or loose debris remain in the chamber. The lid and both latches are secure.
The exhaust hose connections are secure, and purifier operation and exhaust airflow are normal.
After replacing the filter, you may reset the “Purifier Filter” maintenance timer on the maintenance page. Do not reset it if you have only wiped the chamber and have not replaced the filter.